Schließen Zurück Alle Abschnitte einklappen
Prozess-Datensatz: ArmaComfort® Barrier (de) en

Kerninformationen des Datensatzes
Ort PL
Erläuterungen zur geographischen Repräsentativität -
Referenzjahr 2025
Name
ArmaComfort® Barrier
Anwendungshinweis für Datensatz The life cycle analysis (LCA) of the declared products covers: product stage – modules A1-A5, end of life – modules C1-C4 and benefits and loads beyond the system boundary – module D (cradle-to-gate with options) in accordance with EN 15804+A2 and ITB PCR A . Energy and water consumption, emissions as well as information on generated wastes were inventoried and were included in the calculations. It can be assumed that the total sum of omitted processes does not exceed 5% of all impact categories. In accordance with EN 15804+A2, machines and facilities (capital goods) required for the production as well as transportation of employees were not included in LCA.
Technisches Anwendungsgebiet Products covered by this EPD are: ArmaComfort Barrier B, ArmaComfort Barrier B Alu, ArmaComfort Barrier P, Reflamex. ArmaComfort Barrier B and B Alu Flexible, mass-loaded sheet based on EVA-EPM that reduces airborne sound transmission for a quieter environment. Black color. Does not contain lead, bitumen and halogen. 100% recyclable material. B- Alu has an alu foil on top. ArmaComfort Barrier B and B-Alu are available with and without self-adhesive. Designed for the building market and light industry Avg grammage is 3,2 kg/m2. ArmaComfort Barrier P (Reflamex, Reflamex PRM) High acoustic and fire performance mass loaded sound barrier based on EVA-IIR. White cream to light grey color. Flexible sheet to reduce airborne sound transmission. 100 % recyclable material. It´s available with and without self-adhesive tape. Used for transportation and building. Avg grammage 4,3 kg/m2 and 8,7 kg/m2. ArmaComfort Barriers are designed for long-term durability inside normal buildings environments or on internal equipment. The expected service life is typically 20 years when installed and maintained properly. They cannot be exposed to extreme conditions like prolonged direct sunlight, high temperature or chemical exposure, therefore the real service life is project dependent and is specified individually for each application and use case scenario. ArmaComfort Reflamex, being a high-performance fire-resistant material and high acoustic transmission noise reduction, is also designed for long-term use in industrial, transportation, building and commercial applications. The expected service life can be 20 years, depending on the installation environment and maintenance practices. The real service life is project dependent and is specified individually for each application and use case scenario. Technical information of products can be found at: https://www.armacell.com/en-NL/about-armacomfort https://www.armacell.com/en-NL/armacomfort-barrier-b -
Allgemeine Anmerkungen zum Datensatz The data selected for LCA originate from ITB-LCI questionnaires completed by Armacell and verified during data audit. No data collected is older than five years and no generic datasets used are older than ten years. The representativeness, completeness, reliability, and consistency is judged as very good. The background data for the processes come from the following resources database Ecoinvent v.3.11. Specific (LCI) data quality analysis was a part of the input data verification. The allocation rules used for this EPD are based on general ITB’s document PCR A (EN 15804+A2). Input and output data from the production is inventoried and allocated to the production on the mass basis. The declared product’s recipes were used for the calculations, based on specific substances included in the production. All materials and energy consumption inventoried in factory were included in calculation. Office impacts were not taken into consideration. In the assessment, all significant parameters from gathered production data are considered, i.e. all material used per formulation, utilised thermal energy, internal fuel and electric power consumption, direct production waste, and all available emission measurements.
Copyright Ja
Eigentümer des Datensatzes
Quantitative Referenz
Referenzfluss(flüsse)
Biogener Kohlenstoffanteil
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Zeitliche Repräsentativität
Datensatz gültig bis 2030
Erläuterungen zur zeitlichen Repräsentativität "2025-12-18" - "2030-12-18"
Technologische Repräsentativität
Technische Beschreibung inklusive der Hintergrundsysteme -

Parameter zur Beschreibung des Ressourceneinsatzes und sonstige Umweltinformationen

IndikatorRichtungEinheit Rohstoffbereitstellung
A1
Transport
A2
Herstellung
A3
Transport
A4
Einbau
A5
Abbruch
C1
Transport
C2
Abfallbehandlung
C3
Beseitigung
C4
Recyclingpotential
D
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 14.7
  • 0
  • 0.0752
  • 0
  • 0
  • 0
  • 0
  • 65
  • 41.4
  • -39.2
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.0814
  • 0.00111
  • 0.00147
  • 0.00199
  • 0.0000301
  • 0.000012
  • 0.000132
  • 1.12
  • 0.000095
  • -1.12
Input
  • 0.0513
  • 0.000014
  • 0.00000863
  • 0.0000219
  • 1.52E-7
  • 6.08E-8
  • 0.00000146
  • 0.00000119
  • 0.00000178
  • -0.00000357
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0000387
  • 0
  • -0.0000555
Input
  • 0.0313
  • 0.000322
  • 0.0075
  • 0.000745
  • 0.000994
  • 0.000398
  • 0.0000497
  • 0.00396
  • 0.00391
  • -0.00447
Output
  • 0.658
  • 0.00349
  • 0.0153
  • 0.00664
  • 0.00268
  • 0.00107
  • 0.000443
  • 0.0167
  • 0.000465
  • 0.0219
Output
  • 3.75
  • 0.0738
  • 0.651
  • 0.118
  • 0.181
  • 0.0723
  • 0.00786
  • 1.46
  • 5.25
  • 1.47
Output
  • 0.0000325
  • 7.72E-7
  • 0.000016
  • 4.42E-7
  • 5.2E-8
  • 2.08E-8
  • 2.95E-8
  • 0.0000235
  • 6.49E-8
  • 0.0000269
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.00113
  • 0.0000182
  • 0.000946
  • 0.0000183
  • 0.00000232
  • 9.29E-7
  • 0.00000122
  • 0.000884
  • 0.00000444
  • 0.000907
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0

IndikatorEinheit Rohstoffbereitstellung
A1
Transport
A2
Herstellung
A3
Transport
A4
Einbau
A5
Abbruch
C1
Transport
C2
Abfallbehandlung
C3
Beseitigung
C4
Recyclingpotential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 58.3
  • 2.39
  • 9.2
  • 5.92
  • 0.346
  • 0.138
  • 0.395
  • 5.85
  • 0.263
  • -14.8
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0000287
  • 5.66E-7
  • 8.04E-7
  • 0.00000141
  • 8.26E-9
  • 3.3E-9
  • 9.43E-8
  • 0.00000318
  • 2.66E-8
  • -0.00000341
Acidification potential, Accumulated Exceedance (AP)
  • 0.0142
  • 0.000355
  • 0.00176
  • 0.00162
  • 0.000232
  • 0.0000928
  • 0.000108
  • 0.0326
  • 0.0000841
  • -0.00315
Depletion potential of the stratospheric ozone layer (ODP)
  • 6.23E-8
  • 3.38E-9
  • 1.35E-8
  • 9.23E-8
  • 1.21E-10
  • 4.8E-11
  • 6.15E-9
  • 2.5
  • 3.05E-10
  • -2.14E-8
Eutrophication potential - freshwater (EP-freshwater)
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Eutrophication potential - marine (EP-marine)
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.158
  • 0.000112
  • 0.0285
  • 0.00136
  • 0.0000591
  • 0.0000236
  • 0.0000909
  • 0.221
  • 0.0000902
  • -0.0632
Global Warming Potential - fossil fuels (GWP-fossil)
  • 3.3
  • 0.17
  • 0.539
  • 0.399
  • 0.0219
  • 0.00877
  • 0.0266
  • 1.87
  • 0.126
  • -1.01
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.00185
  • 0.0000566
  • 0.0000792
  • 0.000157
  • 0.00000343
  • 0.00000137
  • 0.0000104
  • 0.000608
  • 0.00000677
  • -0.000859
Global Warming Potential - total (GWP-total)
  • 3.15
  • 0.17
  • 0.567
  • 0.4
  • 0.0219
  • 0.00877
  • 0.0267
  • 2.1
  • 0.127
  • -1.08
Global warming potential except emissions and uptake of biogenic carbon (GWP-IOBC/GHG)
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Photochemical Ozone Creation Potential (POCP)
  • 0.0122
  • 0.000589
  • 0.00142
  • 0.00163
  • 0.0000824
  • 0.000033
  • 0.000109
  • 0.044
  • 0.000149
  • -0.00178
Water (user) deprivation potential (WDP)
  • 1.24
  • 0.0117
  • 0.325
  • 0.0274
  • 0.00662
  • 0.00265
  • 0.00183
  • 0.146
  • 0.00125
  • -0.157

IndikatorEinheit Rohstoffbereitstellung
A1
Transport
A2
Herstellung
A3
Transport
A4
Einbau
A5
Abbruch
C1
Transport
C2
Abfallbehandlung
C3
Beseitigung
C4
Recyclingpotential
D
1Diese Wirkungskategorie behandelt hauptsächlich die mögliche Wirkung einer ionisierenden Strahlung geringer Dosis auf die menschliche Gesundheit im Kernbrennstoffkreislauf. Sie berücksichtigt weder Auswirkungen, die auf mögliche nukleare Unfälle und berufsbedingte Exposition zurückzuführen sind, noch auf die Entsorgung radioaktiver Abfälle in unterirdischen Anlagen. Die potenzielle vom Boden, von Radon und von einigen Baustoffen ausgehende ionisierende Strahlung wird ebenfalls nicht von diesem Indikator gemessen.
2Die Ergebnisse dieses Umweltwirkungsindikators müssen mit Bedacht angewendet werden, da die Unsicherheiten bei diesen Ergebnissen hoch sind oder da es mit dem Indikator nur begrenzte Erfahrungen gibt.
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Potential incidence of disease due to PM emissions (PM) 2
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Soil quality index (SQP) 2
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0